CEILING TILES (Mineral Fiber - Fine Fissure)
Instructions for Installation
- When fixing the mineral fiber ceiling panels, please obey the design construction of the products.
Please be assured that the firmness and the planes of joint.
- The environment of installing or using should provide a relative humidity of not more than 80%.
- You should firstly complete all the wet projects inside, and then start to set up the mineral fiber
ceiling.
- Generally speaking, if you need load-bearing tiles, use heavy T-grid please, further more, further
more, you’d better separately design and fix the big lamps or other heavy objects.
- Put on clean gloves when working, so as to keep the panels clean and tidy.
- After finishing installation, pay attention to ventilate the room and close the doors or windows
when raining.
| NORMAL SIZE |
THICKNESS (mm) |
EDGE DETAILS |
|
| 2×2;2×4; 595× 595mm,595×1195mm |
12 |
Square/Regular |
| 2×2;2×4; 595× 595mm,595×1195mm |
14 |
Square/Regular |
| 2×2;2×4; 595× 595mm,595×1195mm |
15 |
Square/Regular |
|
|
| NRC |
0.50-0.60 |
| CAC |
25-30 |
| Fire Rating |
Class A |
| Light Reflection |
0.7 |
| Sagging Resistant Properties |
Warranty against visible sag |
| Humidity Resistance |
Resistance to 90% relative humidity |
| Durability |
Standard |
|
|
| Manufacturing Process |
Dry-processed |
| Density |
250-320KGS/m3 |
| Surface Finish |
250-320KGS/m3 |
|
|
|
| |
|
|
|